Huber Chiller
Huber_Minichiller 300 OLÉ

Chiller with air-cooled refrigerating unit and circulation pump. Evaporator(cooler). tank and housing of stainless steel. Pressure-suction pump made of industrial plastic material. Digital Temperature adjustment and digital temperature display. Level Indicator with sight glass
OLÉ controller
The controller combines state-of-the-art technology with simple operation. Models with OLÉ controller are suitable for routine tasks in research and industry and are convincing as practice oriented basic equipment.
· Large, bright OLED display
· Simple operation with menu navigation
· Simultaneous display of set point, internal temperature, Tmin and Tmax
· USB (Device) and RS232 interfaces
· Autostart function for power failure
Option
Pt100 sensor connection #10519 to display (not control) e.g. of the process temperature (only available factory fitted, additional charge)
※ 4-year warranty – registration required.
Technical data according to DIN 12876
| Operating temperature range | -20...40 (80)*** °C digital |
|---|---|
| Internal temperature sensor | Pt100 |
| Resolution of display | 0,1 K |
| Interface digital | USB (Device), RS232 Interface |
| Temperature stability at -10°C | 0,5 K |
| Alarm message | optic, acoustic |
| Safety classification | I / NFL |
| Cooling power | at 15°C : 0,6 kW / at 0°C : 0,5 kW / at -10°C : 0,35 kW / t -20°C : 0,15 kW |
| Refrigeration machine | air-cooled, natural refrigerant |
| Refrigerant (ASHRAE, GHS) | R-290 (A3, H220) |
| Global Warming Potential (GWP) | 0,02 |
| Refrigerant quantity | 0,085 kg |
| Circulation pump | Pressure- and suction pump max. delivery : 24 l/min max. delivery pressure : 0,7 bar max. delivery (suction) : 8 l/min max. delivery pressure (suction) : 0,4 bar |
| Pump connection | M16x1 male min. filling capacity : 2,8 L expansion tank : 2,2 L |
| Overall dimensions WxDxH ** | 225x360x380 mm |
| Net weight | 23 kg |
| Sound pressure level +/- 4 dB(A) | 53 dB(A) |
| Power supply requirement | 208-240V 1~/2~ 50/60Hz max. current : 4:00 AM / min. Fuse : 10A / max. Fuse : 16A |
| Pressure equipment category | Art. 4.3 PED |
| Degree of Protection | IP20 min. ambient temperature : 5 °C max. ambient temperature : 40 °C |
| from Serial-No | 406972 1.2/20 |
※ Technical details and dimensions are subject to change. No liability is accepted for errors or omissions. Illustrations can deviate from the original.
Included Accessories
· hose connector NW12 #6087
· sleeve nuts thread M16x1#6089
· blank plug #6088
· cover expansion vessel #25178
Optional accessories
· Drain valve #6839
· temperature control / -connection hoses, thermofluids
· further accessories
· etc.: see catalog.
Output data valid for
Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.
In accordance with EN60034-1 the following voltage and frequency tolerances are valid
Voltage + / – 5% with a simultaneous frequency tolerance of + / – 2%
- ※ Example
- -5% voltage and + 2% frequency -> not allowed!
-5% voltage and - 2% frequency -> allowed
Information to Electromagnetic compatibility
Classification (disturbance) to EN55011: Class A, Group 1
- ※ Special Case
- Acetone and Polyglycol :
The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).
It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.
A more resistant plastic is available on request at an additional cost.
Standard delivery conditions – Power cable configuration:
1. Single / two-phase devices (100V to 240V) –> with power cable and country-specific plug (please specify when ordering)
2. Three-phase devices with current consumption less than 63A -> with cable, without plug
3. Three-phase devices with current consumption greater than 63A -> without cable, without plug
This equipment is compliant to US-SNAP and all applicable EU laws. The US-SNAP end-use for this equipment is the industrial process refrigeration. Certification by a Notified Body upon request.
** Please respect space requirements. See wperating conditions at www.huber-online-com
*** Permissible temperature in return line 80 °C